Actually got your inquiry about the low-temp sterilizer, and we've been supplying these to pharma factories for years now—it's the 304 anticorrosive stainless steel chamber that makes a real difference when you're running ethylene oxide cycles day in and day out, basically prevents pitting from the gas exposure.

The working pressure sits at -60 kPa, which is pretty much where you need it for proper gas penetration into wrapped instrument trays or long tubing sets, and humidity range of 45%-75% is what we typically recommend for most loads, though some customers find they need to tweak that for dense packaing.

380V power supply is standard for industiral setups, and the LCD display gives you real-time updates on the cycle—temperature alarm kicks in if things go above setpoint, which matters because you're running low-temperature disinfection mode (usually around 55°C or so) and you don't want that creeping up on delicate plastics or electronics that can't handle autoclave heat.

We include sterilization information recording and printing as a built-in function, so you get a paper trail for every cycle without needing a separate data logger, and most buyers go with the customizable trademark option if they're branding for internal use—lead time is usually 20-30 days, but confirm stock before ordering.

One thing to note: this isn't suited for anhydrous powders or oils, as ethylene oxide needs some moisture to activate, and the chamber materail handles most medical-grade instruments well but avoid aluminum components that can corrode under the gas mixture (we've seen that happen with older tooling).
Just one piece. We don't require a bulk order, so you can start with a single unit to test or scale up later.
The unit is 100% quality guaranteed and meets GMP standards. We provide a user manual, and you can request specific certifications like material or test reports upon inquiry.
The standard chamber is 304 anticorrosive stainless steel, which is highly durable for ethylene oxide sterilization. Customization is limited to the trademark, not the material, to ensure performance.
Lead time depends on your order quantity and current production schedule, but for a single unit, we usually ship within 15-30 days after confirmation. Contact us for exact timing.
The low temperature mode operates at around -60 kPa and 45%-75% humidity, using ethylene oxide gas to sterilize heat-sensitive items like plastics or electronics. It's safe for those materials when used per the manual, and the ultra high temperature alarm prevents overheating.