We can customize the labeling and packaging pretty much however you need it, along with the oxygen concentration range from 21-100% if your batch calls for something specific—just note the MOQ scales with the changes. The 10.4 inch TFT display is actually bright enough for most ICU lighting conditions, and you get the full range of tidal volume from 50ml up to 1500ml with a display readout that shows 0-2000ml.
The respiratory rate runs form 1 to 99 bpm which covers neonates to adults, but we typically see most orders for the 10-30 bpm range in hospital settings. Backup power is rated at 4 hours so you've got decent coverage for outages, though real-world runtime depends on the load and battery age (usually 3-4 hours give or take). The I:E ratio goes from 4:1 down to 1:4 which gives you flexibility for different patient needs.

You get the standerd ventilation modes—A/C, IPPV, SIPPV, IMV, SIMV, Standby, SPONT, and MANUAL—so it basically covers what an ICU ventilator should do. The PEEP is adjustable from 0 to 10cmH2O, and what it does is let you dial in the expiratory pressure. Also, we include the manual mode for situations where you need full control.
is the warranty runs only 1 year which is shorter than some competitors, but the unit itself has a metal and plastic chassis that holds up well in daily use. The CE cerification is there so you'll pass most regulatory checks, and we usually have stock on the YY-700B ADV model—though confirm lead time if you're ordering more than 50 units or so.

We've had buyers who needed the SIMV rate specific settings for neonatal protocols, so we can adjust that in firmware if you give us the numbers. The backup power is a sealed lead-acid battery inside the chassis, which is heavier than lithium but cheaper to replace. Most facilities go with the 4-hour backup option, though our company can spec a smaller battery if weight is a concern.
The tidal volume display range goes up to 2000ml on screen even though actual delivrey stops at 1500ml—so just be aware of that discrepancy if you're tracking exact volumes in charting. It's fine for clinical use, but we thought you should know since it's not on every spec sheet.
Our MOQ is 10 units per model. If you need fewer for a trial, we can discuss it—just let us know your situation.
Standard lead time is 25-30 working days after order confirmation. Customization like branding or software tweaks may add a few days.
Yes, we include the CE certificate and a Declaration of Conformity with every shipment. If you need additional country-specific docs, just ask.
Yes, you can set tidal volume as low as 50ml and up to 1500ml. The displayed range goes to 2000ml, but the set range is 50-1500ml. Accuracy is within ±15% or ±5ml, whichever is bigger.
The ventilator is packed in a sturdy carton with foam inserts. Store it in a dry, clean place at -10°C to 50°C, with humidity under 80% non-condensing.