Account
Inquiry
Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range
Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range
Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range
Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range
Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range

Professional Hospital Ventilator CWH-3010 with 5-80cmH2O Pressure Range

US$ 1.00 ~ 99999.00
Min.Order: 1
Product origin: Nanjing, Jiangsu, China
Category: Medical Equipment
Product Name: Medical Equipment
Availability:In Stock
Product Review : 8 Reviews
Infringement complaint:
* Please contact the supplier via whatsapp first before placing an order
  • Model NO. : CWH-3010
  • Type : Emergency Ventilator
  • Application : Adult and Pediatric Patients
  • Drive System : Gas Driven
  • Gas Source : Oxygen, Air
  • Tidal Volume Range : 20-2000ml (10ml increment)
  • Pressure Range : 5-80cmH2O
  • Respiration Rate : 1-100 bpm
  • Oxygen Concentration : 21%-100%
  • Ventilation Modes : VCV, SIGH, SIMV, SIPPV
  • Dimensions : 450×550×1400mm (L×H×W)
  • Net Weight : 65kg
  • Operating Temperature : 5-40°C
  • Storage Temperature : -10-40°C
  • Certifications : ISO 9001, 13485, CE

The presure range hits 80cmH2O, which is basically the highest you'll see outside an ICU—most units max out at 60 or so. We've handled enough calls where a patient with stiff lungs needed that extra headroom, so it's not just a number on a spec sheet.

CWH-3010 ICU Ventilator

It's gas-driven, so you don't need a compressor humming in teh background—oxygen and air sources are all you need, but check lead time on the oxygen blender if you're running high-flow. The tidal volume goes form 20ml to 2000ml in 10ml increments, which matters more for neonates than you'd think—most buyers go with the 10mg... wait, that's a different product—anyway, the 10ml step is tighter than typical 50ml jumps on cheaper units.

Ventilator Control Panel

For adult and pediatric patients, you'll use VCV or SIMV mostly—SIGH is a nice touch for post-op but not critical. waveforms (P-T, F-T, V-T) are actually readable on the display, not just a blur of lines like some budget models we've seen come through.

It weighs 65kg and measures 450×550×1400mm—you'll need two people to move it, and the casters are okay but not great on carpet. Operating temp is 5-40°C, so it'll handle a warm room fine, but storage at -10°C means don't leave it in the truck overnight in winter.

Ventilator in Clinical Setting

ISO 9001 and 13485 plus CE—that's what you need for hospital procurement, and we've got the, though lead times are roughly 4-6 weeks right now. It's not suited for transport ventilators—too heavy, and the gas consumption is higher than a portable unit—but for ER or ICU overflow, it's a solid workhorse.

Ventilator Waveform Display

One thing buyers don't always ask: the alarm thresholds are adjustable per mode, but the default settings for high pressure tend to be conservative—you'll want to tweak them for SIPPV or you'll get nuisance alarms.

Frequently Asked Questions

What is the minimum order quantity for the CWH-3010 ventilator?

Our MOQ for the CWH-3010 is typically 2 units for first-time orders, but we can discuss smaller quantities for sample evaluation or specific project needs.

How long is the lead time for the CWH-3010, and do you offer expedited shipping?

Standard lead time is 25-35 working days after order confirmation. Expedited shipping is available on request, usually adding a surcharge to cover air freight.

Do you provide ISO 13485 and CE certificates with the shipment?

Yes, we include copies of ISO 9001, ISO 13485, and CE certificates with every CWH-3010 shipment. They're also available for download from our partner portal.

Can I get the CWH-3010 with a customized tidal volume increment or pressure range?

The tidal volume increments are fixed at 10ml, and the pressure range at 5-80cmH2O per the standard design. Customization beyond these specs would require a separate engineering review with a minimum order of 50 units.

What are the recommended storage conditions for the CWH-3010 during shipping or long-term storage?

The ventilator should be stored in a dry environment between -10°C and 40°C. Keep it in its original packaging with the transport locks engaged to avoid damage.

Home
Account
Order
Categorys