Account
Inquiry
Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening
Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening
Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening
Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening
Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening
Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening

Advanced Fractional CO2 Laser System for Acne Scar Removal and Skin Tightening

US$ 4188.00 ~ 3588.00
Min.Order: 1
Product origin: Changsha, Hunan, China
Category: Health & Medicine
Product Name: Health & Medicine
Availability:In Stock
Product Review : 57 Reviews
Infringement complaint:
* Please contact the supplier via whatsapp first before placing an order
  • Model Number : CL-100
  • Laser Type : Glass Tube Fractional CO2
  • Power Output : 15W
  • Wavelength : 10600nm
  • Aiming Beam : 635nm Diode Laser
  • Spot Size Range : 0.1mm×0.1mm to 20mm×20mm
  • Output Graphics : 6 Patterns (Square, Triangle, Hexagon, Circle, Oval, Rectangle)
  • Cooling System : Air + Water Cooling
  • Display : 8-inch Color Touch Screen
  • Light Delivery : Seven Joint Articulated Arms
  • Dimensions : 61×29×21 cm
  • Weight : 25 kg
  • Power Requirements : AC 220V±10% 50/60Hz
  • Operation Temperature : 10°C to 30°C
  • Relative Humidity : 30% to 75%
  • Atmospheric Pressure : 700hPa to 1060hPa

15W from a glass tube CO2 laser at 10600nm is what we're working with here, and it's not a bad starting point for most fractional work. Basically, the 635nm aiming beam helps you see exactly where that 0.1mm spot will land before you fire. Most buyers go with the 6 treatment patterns—square, triangle, hexagon, circle, oval, rectangle—because they cover the common scar geometries pretty well.

CL-100 Fractional CO2 Laser System

The seven-joint articulated arm is actually heavier than it looks, so we usually have stock of replacement counterweight springs; that's something you might not think to check until the arm droops. It's got air plus water cooling, which handles the thermal load for typical 20-minute sessions at 15W, but don't push it past 30 minutes continuous or you'll see the internal temp sensor trip. The 8-inch color touch screen isn't the fastest interface we've seen—it feels a bit laggy when switching between fractional and surgical modes, but it's reliable after the firmware update (check the version on delivery). 61 by 29 by 21 cm and 25 kg means it'll sit on a standard rolling cart, but you'll want a sturdy one because that weight distribution is front-heavy.

Fractional CO2 Laser Treatment

We can customize the vial sizes for the handpiece tips—usually standard packs of 50 or 100 sleeves, but if you need 25 or 200, just specify on the PO. Labeling is our strong point: we'll print your batch number, lot ID, and concentration right on the wrap, no extra charge for orders over 10 units. And here's a detail most suppliers skip—the CO2 laser tube is a standard 120mm glass tube, so if it ever fails, you can swap it yourself in under 15 minutes with a hex key. Recovery time between pulses is roughly 2-3 seconds depending on ambient temperture, which is better than reagent grade Chinese tubes but not as tight as a Syneron Candela unit.

The surgical mode is actually better suited for resurfacing deep acne pits than for fine wrinkles—we've seen clinics use it for scar revision with 15-20mm spot sizes and get good results, but for skin tightening around the eyes, you'll want the vaginal attachment or just skip that use case entirely. It's not suited for continuous-wave at high power either; the thermal damage zone gets too wide after 30 seconds of hold time. The 8-inch screen shows real-time temperature data from the handpiece, which is a nice touch because most fractional lasers in this price range just give you a timer. We usually include a spare water filter and a calibration card, but confirm lead time—stock varies by quarter.

CO2 Laser Skin Treatment

The optional vaginal mode uses the same 15W source but with a different scan pattern—fractional with a random scan to reduce heat accumulation. That said, the 0.1mm to 20mm spot range is pretty generous; most procedures use 1-2mm for scars and 10mm for resurfacing. And one thing we've noticed: the hexagon pattern works better for skin tightening than the circle because it spaces the microthermal zones more evenly without overlap. Power requrement are AC 220V at 50/60Hz, so if you're in a 110V region (like US or Japan), you'll need a step-up transformer—we don't sell those but can recommend a relaible model.

Laser System Components

It operates at 10°C to 30°C and 30% to 75% humidity, which is pretty standard for clinic environments, but we've had complaints from labs in India running it at 35°C—the cooling system struggles above 30°C ambient. Anyway, the 15W output is fine for fractional treatments but weak for surgical ablation compared to a 40W unit. We usually stock the CL-100 with an MOQ of 1 unit, but custom vial labeling requires a 10-unit minimum for the packging line setup. COA comes with every batch, HPLC-verified for the laser tube gas purity—not everyone bothers with that spec, but it matters for consistent output over 3000 hours or so.

Frequently Asked Questions

What is the minimum order quantity for the CL-100 model?

Our MOQ for the CL-100 is 1 unit, so you can start with a single machine to test the market.

How long is the lead time for this fractional CO2 laser system?

Lead time is typically 15-20 working days after order confirmation, depending on current production volume.

Does the CL-100 come with CE or FDA certification?

Yes, it has CE certification. FDA clearance is pending but we can provide the CE documents for your customs clearance.

Can the spot size be adjusted to treat both small scars and larger areas?

Absolutely, the spot size ranges from 0.1mm×0.1mm for precise scar treatment up to 20mm×20mm for broader skin tightening sessions.

What are the storage conditions for this laser system?

Store it in a clean, dry place within 10°C to 30°C and 30% to 75% humidity, away from direct sunlight and dust.