So when a clinician needs to check intraocular pressure in a patient who can't sit upright—maybe post-surgery or bedridden—they can switch the unit to horizontal mode and still get consistent readings, and that's actually where this model stands out from the standard handheld units.

The rebound technology works by measuring how the probe decelerates after tapping cornea, which gives you a pressure reading within about 3-70mmHg, with accuracy sitting at ±1.5mmHg in the lower range (3-25mmHg) and ±2.5mmHg up to 70mmHg, and we've found most buyers go with the 10mg probe tip for general use.

It's CE, FDA, and ISO13485 certified, which pretty much covers the major regulatory boxes for clinical export, and we usually have stock on the EG-RTM500, but confirm lead time for large orders since wireless printer modules (not included by default for some markets) can add 20 days or so.

One thing you might not think to ask—the operating tempearture range is +5°C to +40°C, but storage can handle -20°C to +55°C, so it's fine for shiping without climate control in most cases, though the humidity cap at 80% operating means you wouldn't want to leave it in a steamy exam room overnight.

Power comes form two AA batteries (DC 3V), and while the 6kg weight makes it portable but not pocket-sized, the 335×320×200mm footprint fits nicely on a cart or shelf.

Anyway, it's not meant for pediatric or anesthesia-free patients since rebound still requires corneal contact, but for routine adult screening it beats applanation tonometry on speed and patient comfort every time, and we keep the TDS and COA on file for each shipment.
We typically require a MOQ of 10 units for first-time orders, but we can discuss smaller trial quantities if you're just testing the market. Let us know your volume and we'll work something out.
Standard lead time is around 15-20 working days from order confirmation and payment. If you need a rush order, we can sometimes expedite to 10-12 days depending on stock.
Yes, we include copies of the CE, FDA, and ISO13485 certificates with every shipment. You can also request them upfront for your registration or tender process.
It's primarily designed for human use with its vertical and horizontal measurement modes, but the rebound technology works well for animal eyes too. Just note the accuracy specs are calibrated for human IOP ranges, so you'd need to verify performance for veterinary applications.
Keep it in a dry place with storage temperature between -20°C and +55°C and humidity at or below 95%. Avoid direct sunlight and make sure the batteries are removed if storing for over a month to prevent leakage.